Primary Type-B EPR AGL Cables

Ground Lighting Cable Type B, Unscreened
ICEA S-96-659/NEMA WC 71 - FAA specifications L-824 (150/5345-7F)

Construction

Conductor :Strand of annealed bare or tinned copper wire in accordance with ICEA S-96-659/NEMA WC 71 and IEC 60228
Semiconductive :Extruded semiconductive material in accordance with ICEA S-96-659/NEMA WC 71
Insulation :EPR in accordance with ICEA S-96-659/NEMA WC 71
Outer Jacket :CPE-XL-HD, CR-HD or CSPE-HD material in accordance with ICEA S-96-659/NEMA WC 71

Technical Features

Operating Temperature : -15/90 °C
Rated Voltage : 5 kV
Test Voltage : 13 kV
Bending Radius : 12 x Outer diameter
Design Standard : ICEA S-96-659/NEMA WC 71

Application : Power transmission for airport lighting circuits.

Insulation and outer sheath colors can be modified upon customer’s request.

Technical Data
Code
Construction
Cross – Section
Copper Factor
(kg/km)
Weight (approx)
(kg/km)
Outer Dia. (approx)
(mm)
MCDR at 20 °C
( /km)
MCCC at 90 °C CT, at 45 °C AT
(A)
TERAAAE BCL2/EXSC/EPR/CPE 1   x   6   mm2 53 144 9.7 3.08 52
TERAAAR BCL2/EXSC/EPR/CR 1   x   6   mm2 53 142 9.7 3.08 52
TERAAAS BCL2/EXSC/EPR/CSPE 1   x   6   mm2 53 143 9.7 3.08 52
KERAAAE TCL2/EXSC/EPR/CPE 1   x   6   mm2 53 144 9.7 3.11 52
KERAAAR TCL2/EXSC/EPR/CR 1   x   6   mm2 53 142 9.7 3.11 52
KERAAAS TCL2/EXSC/EPR/CSPE 1   x   6   mm2 53 143 9.7 3.11 52
TERAAAE BAWGB/EXSC/EPR/CPE 1   x   8   AWG 76 176 10.3 2.14 64
TERAAAR BAWGB/EXSC/EPR/CR 1   x   8   AWG 76 174 10.3 2.14 64
TERAAAS BAWGB/EXSC/EPR/CSPE 1   x   8   AWG 76 175 10.3 2.14 64
KERAAAE TAWGB/EXSC/EPR/CPE 1   x   8   AWG 76 176 10.3 2.22 64
KERAAAR TAWGB/EXSC/EPR/CR 1   x   8   AWG 76 174 10.3 2.22 64
KERAAAS TAWGB/EXSC/EPR/CSPE 1   x   8   AWG 76 175 10.3 2.22 64
TERAAAE BAWGB/EXSC/EPR/CPE 1   x   6   AWG 120 235 11.3 1.35 85
TERAAAR BAWGB/EXSC/EPR/CR 1   x   6   AWG 120 233 11.3 1.35 85
TERAAAS BAWGB/EXSC/EPR/CSPE 1   x   6   AWG 120 234 11.3 1.35 85
KERAAAE TAWGB/EXSC/EPR/CPE 1   x   6   AWG 120 235 11.3 1.4 85
KERAAAR TAWGB/EXSC/EPR/CR 1   x   6   AWG 120 233 11.3 1.4 85
KERAAAS TAWGB/EXSC/EPR/CSPE 1   x   6   AWG 120 234 11.3 1.4 85
MCCC: Maksimum Akım Taşıma Kapasitesi / Maximum Current Carrying Capacity CT: İletken Sıcaklığı / Conductor Temperature
AT: Ortam Sıcaklığı / Ambient Temparature
MCDR: Maksimum DC İletken Direnci / Max. Conductor DC Resistance